Moku:Lab oscilloscope probe compensation

How do I compensate a probe for accurate oscilloscope measurements ?

Written by Paul Cracknell

Updated at February 26th, 2021

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Moku:Go
    Moku:Go Arbitrary Waveform Generator Moku:Go Data Logger Moku:Go Frequency Response Analyzer Moku:Go Logic Analyzer & Pattern Generator Moku:Go Oscilloscope & Voltmeter Moku:Go PID Controller Moku:Go Spectrum Analyzer Moku:Go Waveform Generator Moku:Go Power Supplies Moku:Go Digital Filter Box Moku:Go FIR Filter Builder Moku:Go Lock-in Amplifier
  • Moku:Lab
    Windows Moku:Lab general Moku:Lab Instruments iPad app Software integrations
  • Moku:Pro
    Moku:Pro Instruments
+ More

Moku:Lab oscilloscope can be used to compensate a probe to ensure both accurate measurements of voltage and frequency and also precise waveform representation.

The Moku:Lab oscilloscope has an integrated waveform generator; the video shows the waveform generator being set to 1 kHz, 2 Vpp. The under-compensated signal is then adjusted to slightly over compensated and finally to a well compensated state. This is achieved with the probe in 10:1 setting; the Moku:Lab oscilloscope is also setup to 10x probe.

Under compensated; not true square waveform and amplitude measurement less than actual 2V.



Slightly over compensated, overshoot on leading edge and slight over measurement on amplitude of 2V actual
Accurately compensated,  sharp square wave and accurate 2.000V amplitude measurement



moku:lab oscilloscope probe probe compensation

Was this article helpful?

Yes
No

Related Articles

  • How do I adjust the sampling rate of the oscilloscope?
  • What measurements can the Oscilloscope make?
  • Can I set the channel offset in screen divisions while zooming?

Sitemap

  • Moku:Lab
  • Instruments
  • Software
  • Company
  • Support
  • Store
  • Terms & Conditions
  • Privacy Policy

Offices

United States
+1 (619) 332-6230
740 Lomas Santa Fe Dr
Suite 102
Solana Beach, CA 92075

Australia
+61 2 6171 9730
243 Northbourne Avenue
Suite 2
Lyneham, ACT 2602

Follow us

Youtube LinkedIn

官方微信

Contact us
© 2021 Liquid Instruments. All rights reserved.

Definition by Author

0
0
Expand