Dynamic Amplitude Adjustment

Written by Dylan Perez

Updated at December 19th, 2024

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Moku:Go
    Moku:Go General Moku:Go Arbitrary Waveform Generator Moku:Go Data Logger Moku:Go Digital Filter Box Moku:Go FIR Filter Builder Moku:Go Frequency Response Analyzer Moku:Go Logic Analyzer & Pattern Generator Moku:Go Oscilloscope & Voltmeter Moku:Go PID Controller Moku:Go Spectrum Analyzer Moku:Go Waveform Generator Moku:Go Power Supplies Moku:Go Lock-in Amplifier Moku:Go Time & Frequency Analyzer Moku:Go Laser Lock Box Moku:Go Phasemeter
  • Moku:Lab
    Moku:Lab General Moku:Lab Arbitrary Waveform Generator Moku:Lab Data Logger Moku:Lab Digital Filter Box Moku:Lab FIR Filter Builder Moku:Lab Frequency Response Analyzer Moku:Lab Laser Lock Box Moku:Lab Lock-in Amplifier Moku:Lab Oscilloscope Moku:Lab Phasemeter Moku:Lab PID Controller Moku:Lab Spectrum Analyzer Moku:Lab Time & Frequency Analyzer Moku:Lab Waveform Generator Moku:Lab Logic Analyzer/Pattern Generator
  • Moku:Pro
    Moku:Pro General Moku:Pro Arbitrary Waveform Generator Moku:Pro Data Logger Moku:Pro Frequency Response Analyzer Moku:Pro Oscilloscope Moku:Pro PID Controller Moku:Pro Spectrum Analyzer Moku:Pro Waveform Generator Moku:Pro Lock-in Amplifier Moku:Pro Laser Lock Box Moku:Pro Digital Filter Box Moku:Pro FIR Filter Builder Moku:Pro Phasemeter Moku:Pro Multi-instrument Mode Moku:Pro Logic Analyzer/Pattern Generator Moku:Pro Time & Frequency Analyzer
  • Python API
  • MATLAB API
  • Arbitrary Waveform Generator
  • Data Logger
  • Digital Filter Box
  • FIR Filter Builder
  • Frequency Response Analyzer
  • Laser Lock Box
  • Lock-in Amplifier
  • Oscilloscope
  • Phasemeter
  • PID Controller
  • Spectrum Analyzer
  • Time & Frequency Analyzer
  • Waveform Generator
  • Logic Analyzer & Pattern Generator
  • Multi Instrument Mode
  • Moku Cloud Compile
  • Moku general
  • LabVIEW
+ More

The Dynamic amplitude setting in the Frequency Response Analyzer is a powerful tool that allows you to get the most accurate frequency response of your device under test (DUT). When using the frequency response analyzer, the signal going to your DUT should usually have the largest amplitude possible to ensure that you have a high resolution curve. However, when the signal is too high, the DUT can go into saturation, but when the signal is too low, the curve will have poor resolution and be inundated with noise. The dynamic amplitude setting will dynamically reduce the amplitude of the Moku output to prevent your DUT from going into saturation, while giving you the most high resolution curve possible. 

Saturation is when the output of your DUT stops responding to increases in the input. Ideally, the output of the DUT will respond proportionally to changes in the input. When the DUT is in saturation, the output will remain constant, independent of any increases at the input. This results in your frequency response curve being inaccurate and therefore invalidates your results. 

Fig. 1: Saturation warning in Moku software

The dynamic amplitude setting will never increase the maximum voltage set by the user, only lower the signal when the Moku detects saturation occurring. This allows the user to set the signal amplitude as high as possible, ensuring a clear curve, without worrying about the DUT entering saturation. 

To use this setting, open up the frequency response analyzer on your Moku. Navigate to the settings tab on the right side and turn on the Dynamic amplitude. 

Fig. 2: Location of the Dynamic Amplitude setting in the Frequency Response Analyzer
adaptive volume flexible intensity saturation dynamic amplitude

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Does the Lock-in Amplifier include a PID controller for feedback applications?
  • Can the Lock-in Amplifier output a signal drive a modulator?
  • What if my actuator can't take negative voltages?
  • Measuring impedance with Moku:Go (part 1)

Sitemap

  • Moku:Lab
  • Instruments
  • Software
  • Company
  • Support
  • Store
  • Terms & Conditions
  • Privacy Policy

Offices

United States
+1 (619) 332-6230
12526 High Bluff Dr
Suite 150
San Diego, CA 92130

Australia
+61 2 6171 9730
243 Northbourne Avenue
Suite 2
Lyneham, ACT 2602

Australia
+61 03 7073 3594
700 Swanston Street
Suite 5E, Level 5
Carlton, VIC 3053

Follow us

Youtube LinkedIn

官方微信

Contact us
© 2025 Liquid Instruments. All rights reserved.

Knowledge Base Software powered by Helpjuice

Definition by Author

0
0
Expand